ViewVC Help
View File | Revision Log | Show Annotations | Download File | Root Listing
root/radiance/ray/src/util/trad.hlp
(Generate patch)

Comparing ray/src/util/trad.hlp (file contents):
Revision 2.15 by greg, Thu Sep 28 14:11:45 1995 UTC vs.
Revision 2.18 by gwlarson, Tue Oct 20 11:52:15 1998 UTC

# Line 398 | Line 398 | long as the overall size of the given box is close to
398   size of the space.
399  
400   The Zone entry windows may be manipulated in the following ways.
401 Control-U clears the current window.
401   Control-V pastes the contents of the current selection at the
402   insertion point.
403   Return moves the focus to the next window in the chain.
404  
405 + The "Auto" button may be used to set these values based on the bounding
406 + box of one or more Radiance scene files.
407 +
408 + .Zone.Auto
409 +
410 + Use this button to automatically determine the bounding box for this
411 + zone, based on the output of the "getbbox" command run on one or
412 + more Radiance scene files.
413 + The appropriate scene files are entered via a file
414 + selection dialogue box, which comes up after the button is pressed.
415 +
416 + The reason for selecting specific files rather than running getbbox
417 + on the entire scene is that a zone usually does not include large
418 + external objects, which may be present in the complete scene
419 + description.
420 +
421   .Zone.Detail
422  
423   The "Detail" setting indicates the relative level
# Line 490 | Line 505 | tot_flux is given in watts.
505   (Divide total lumens by 179 lumens/watt to get watts.)
506  
507   The exposure value may either be given as a positive real value, or
508 < as a real value preceeded by a '+' or '-' indicating a positive or
508 > as a real value preceded by a '+' or '-' indicating a positive or
509   negative number of f-stops (powers of two) from the original value.
510  
511   If no exposure is given, pfilt will automatically compute the
# Line 682 | Line 697 | The "Clear" button simply clears the "Name" and "Optio
697   for the convenience of entering a new view.
698   It has no effect on the rad input variables.
699  
685 Note that Control-U will always clear an entry box whose cursor is
686 active.
687
700   .Views.Default
701  
702   The "Set Default" button may be used to make the selected view the
# Line 707 | Line 719 | The standard view up vector may be set to the positive
719   the positive Y axis (+Y), the positive Z axis (+Z), the negative
720   X axis (-X), the negative Y axis (-Y), or the negative Z axis (-Z).
721  
722 < This setting may always be overriden by the "-vu xd yd zd" option,
722 > This setting may always be overridden by the "-vu xd yd zd" option,
723   and will be altered for a particular view if it happens to be
724   parallel to the view direction.
725 +
726 + .Views.Eyesep
727 +
728 + The eye separation is used for generating stereo views of
729 + the scene.
730 + It is the measured distance between a viewer's pupils in world
731 + coordinate units.
732 + It is not used directly by rad, but should be set for other programs
733 + that need it, such as rholo and glrad.
734  
735   .Views.Picture
736  

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines