.\" RCSid $Id: lamptab.5,v 1.1 2021/08/19 06:35:01 greg Exp $ .TH LAMP.TAB 5 2021-08-18 RADIANCE .SH NAME lamp.tab \- table of lamp colors and lumen depreciation factors .SH DESCRIPTION Lamp.tab contains a table of lamp data. The lines are formatted thus: .IP .RI / "light source name re" / .I x y m .PP or .IP .RI / "light source alias re" / .RI ( "light source name" ) .PP The first form gives the color and depreciation of a lamp whose name matches the light source name regular expression. The second gives an alternate name for a light source. Comments beginning with '#' are supported. .SS Notes .IP \(bu Basic regular expressions (original grep) are used. .IP \(bu .I x and .I y are CIE x and y coordinates. These give the color of the light. See .UR https://www.iso.org/standard/74165.html ISO/CIE 11664-3:2019 .UE \*(lqColorimetry \(em Part 3: Cie Tristimulus Values\*(rq for definitions. .IP \(bu .I m is a "coefficient of depreciation." This is a multiplier used to reduce the output of a lamp to the value it would have after it has been in operation for its expected life. It is used to predict the output of a lighting system comprised of many lamps. See the .I IES Lighting Handbook for more information. .IP \(bu Any character except '#' may be used to delimit the light source name regular expression; '/' is conventional, but not required. .IP \(bu Comments begin with '#' and may occur at the end of any line. .IP \(bu Blank lines are ignored. .SH AUTHOR Greg Ward .SH SEE ALSO .BR ies2rad (1), .BR pfilt (1)