# Line 42 | Line 42 | A command argument beginning with an at sign ('@') is
42   replaced by the contents of the given file.
43   The options are the same as for rpict(1), with a few notable exceptions.
44   The
45 < .I "\-r, \-z, \-S, \-P, \-PP"
45 > .I "\-pd, \-r, \-z, \-S, \-P, \-PP"
46   and
47   .I \-t
48   options are not supported, and
# Line 159 | Line 159 | Set focus distance for depth-of-field sampling.
159   If a distance in world coordinates is absent, then the cursor
160   is used to choose a point in the scene on which to focus.
161   (The focus distance setting does not affect rendering in
162 < .I rview,
162 > .I rvu,
163   but can be used in
164   .I rpict
165   with the
166   .I \-pd
167   option to simulate depth-of-field on views saved from
168 < .I rview.)
168 > .I rvu.)
169   .TP
170   .BI frame " [ xmin ymin xmax ymax ]"
171   Set frame for refinement.
# Line 230 | Line 230 | Care must be taken to avoid moving behind or inside ot
230   Restart the image, using the specified number of rendering processes.
231   Usually used after the "set" command.
232   .TP
233 + .BI origin " [ xo yo zo [ xd yd zd ] ]"
234 + Change view origin to the indicated world position
235 + .I "xo yo zo"
236 + looking in the direction
237 + .I "xd yd zd."
238 + If the direction is missing, the current view direction is used.
239 + If the origin is missing, the cursor is used to select the
240 + view origin, and the direction will be determined by the
241 + (reoriented) surface normal.
242 + The view type and size will not be altered, but the up vector
243 + may be changed if the new direction coincides.
244 + .TP
245   .BI pivot " angle [ elev [ mag [ x y z ] ] ]"
246   Similar to the "move" command, but pivots the view about a selected point.
247   The
248   .I angle
249 < is measured in degrees around the view up vector using the right hand rule.
249 > is measured in degrees around the view up vector using the right hand rule,
250 > so a positive value pivots the viewer to the right of the selected point.
251   The optional
252   .I elev
253   is the elevation in degrees from the pivot point; positive raises the view point
# Line 253 | Line 266 | color table selection.
266   .BI rotate " angle [ elev [ mag ] ]"
267   Rotate the camera horizontally by
268   .I angle
269 < degrees.
269 > degrees using the right-hand rule.
270 > A positive value rotates the view towards the left, and a negative value
271 > looks to the right.
272   If an elevation is specified, the camera looks upward
273   .I elev
274   degrees.
# Line 344 | Line 359 | Stop the program.
359   The screen will be redrawn when the program resumes.
360   .SH ENVIRONMENT
361   RAYPATH         the directories to check for auxiliary files.
362 + .br
363   DISPLAY_GAMMA           the value to use for monitor gamma correction.
364   .SH AUTHOR
365   Greg Ward
366   .SH "SEE ALSO"
367 < getinfo(1), lookamb(1), oconv(1), pfilt(1), rad(1), rpict(1), rtrace(1)
367 > getinfo(1), lookamb(1), mkpmap(1),
368 > oconv(1), pfilt(1), rad(1), rpict(1), rtrace(1)

Diff Legend

Removed lines
+ Added lines
< Changed lines