ViewVC Help
View File | Revision Log | Show Annotations | Download File | Root Listing
root/radiance/ray/doc/man/man1/rtcontrib.1
(Generate patch)

Comparing ray/doc/man/man1/rtcontrib.1 (file contents):
Revision 1.17 by greg, Sat Nov 17 01:13:50 2007 UTC vs.
Revision 1.23 by greg, Sun Sep 26 15:51:14 2010 UTC

# Line 9 | Line 9 | rtcontrib - compute contribution coefficients in a RAD
9   ][
10   .B \-V
11   ][
12 < .B \-c
12 > .B "\-c count"
13   ][
14   .B \-fo
15   |
# Line 58 | Line 58 | this file.
58   (No search takes place if a file name begins with a '.', '/' or '~'
59   character.)\0
60   .PP
61 + If the
62 + .I \-n
63 + option is specified with a value greater than 1, multiple
64 + .I rtrace
65 + processes will be used to accelerate computation on a shared
66 + memory machine.
67 + Note that there is no benefit to using more processes
68 + than there are local CPUs available to do the work, and the
69 + .I rtcontrib
70 + process itself may use a considerable amount of CPU time.
71 + .PP
72   By setting the boolean
73   .I \-V
74   option, you may instruct
# Line 86 | Line 97 | rather than radiance, and
97   .I \-V-
98   coefficients contain an additonal factor of PI.
99   .PP
100 + The
101 + .I \-c
102 + option tells
103 + .I rtcontrib
104 + how many rays to accumulate for each record.
105 + The default value is 1, meaning a full record will be produced for
106 + each input ray.
107 + For values greater than 1, contributions will be averaged together
108 + over the given number of input rays.
109 + If set to zero, only a single record will be produced at the very
110 + end, corresponding to the sum of all rays given on the input
111 + (rather than the average).
112 + This is equivalent to passing all the output records through a program like
113 + .I total(1)
114 + to sum RGB values together, but is much more efficient.
115 + Using this option, it is possible to reverse sampling, sending rays from
116 + a parallel source such as the sun to a diffuse surface, for example.
117 + Note that output flushing via zero-direction rays is disabled
118 + for accumulated evaluations.
119 + .PP
120   The output of
121   .I rtcontrib
122   has many potential uses.
# Line 97 | Line 128 | More generally,
128   can be used to compute arbitrary input-output relationships in optical
129   systems, such as luminaires, light pipes, and shading devices.
130   .PP
100 Setting the
101 .I \-c
102 option instructs
103 .I rtcontrib
104 to accumulate values rather than reporting one record per ray.
105 With this option, only a single record will be produced at the very
106 end, corresponding to the sum of all rays given on the input.
107 This is equivalent to passing all the output records through a program like
108 .I total(1)
109 to sum RGB values together, but is much more efficient.
110 Using this option, it is possible to reverse sampling, sending rays from
111 a parallel source such as the sun to a diffuse surface, for example.
112 Care must be taken to perform normalization based on the
113 radiation density and the number of rays sampled.
114 .PP
131   .I Rtcontrib
132   calls
133   .I rtrace(1)
# Line 130 | Line 146 | If instead the
146   .I \-r
147   option is specified, data recovery is attempted on existing files.
148   (If
149 < .I \-c
149 > .I "\-c 0"
150   is used together with the
151   .I \-r
152   option, existing files are read in and new ray evaluations are added
# Line 150 | Line 166 | If the number of bins is known in advance, it should b
166   .I \-bn
167   option, and this is critical for output files containing multiple values
168   per record.
169 + A variable or constant name may be given for this parameter if
170 + it has been defined via a previous
171 + .I \-f
172 + or
173 + .I \-e
174 + option.
175   Since bin numbers start from 0, the bin count is always equal to
176   the last bin plus 1.
177   Set the this value to 0 if the bin count is unknown (the default).
# Line 160 | Line 182 | and
182   .I \-o
183   options to the left of each
184   .I \-m
185 < setting affect only that modifier.
185 > setting are the ones used for that modifier.
186   The ordering of other options is unimportant, except for
187   .I \-x
188   and
189   .I \-y
190   if the
191   .I \-c
192 < is present, when they control the resolution string
192 > is 0, when they control the resolution string
193   produced in the corresponding output.
194   .PP
195   If a
# Line 243 | Line 265 | suitable for manipulation with
265   .I pcomb(1)
266   and related tools.
267   .PP
246 If the
247 .I \-n
248 option is specified with a value greater than 1, multiple
249 .I rtrace
250 processes will be used to accelerate computation on a shared
251 memory machine.
252 Note that there is no benefit to using more processes
253 than there are local CPUs available to do the work, and the
254 .I rtcontrib
255 process itself may use a considerable amount of CPU time.
256 .PP
268   Options may be given on the command line and/or read from the
269   environment and/or read from a file.
270   A command argument beginning with a dollar sign ('$') is immediately
# Line 271 | Line 282 | contributions:
282   .IP "" .2i
283   vwrays \-ff \-x 1024 \-y 1024 \-vf best.vf |
284   rtcontrib \-ffc `vwrays \-d \-x 1024 \-y 1024 \-vf best.vf`
285 < @render.opt \-o c_%s.pic \-m light1 \-m light2 scene.oct
285 > @render.opt \-o c_%s.hdr \-m light1 \-m light2 scene.oct
286   .PP
287   These images may then be recombined using the desired outputs
288   of light1 and light2:
289   .IP "" .2i
290 < pcomb \-c 100 90 75 c_light1.pic \-c 50 55 57 c_light2.pic > combined.pic
290 > pcomb \-c 100 90 75 c_light1.hdr \-c 50 55 57 c_light2.hdr > combined.hdr
291   .PP
292   To compute an array of illuminance contributions according to a Tregenza sky:
293   .IP "" .2i
# Line 287 | Line 298 | RAYPATH                path to search for \-f and \-M files
298   .SH AUTHOR
299   Greg Ward
300   .SH "SEE ALSO"
301 < cnt(1), getinfo(1), pcomb(1), pfilt(1), ra_rgbe(1),
302 < rcalc(1), rpict(1), rtrace(1), total(1), vwrays(1), ximage(1)
301 > cnt(1), genklemsamp(1), getinfo(1), pcomb(1), pfilt(1), ra_rgbe(1),
302 > rcalc(1), rpict(1), rsensor(1), rtrace(1), total(1), vwrays(1), ximage(1)

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines