ViewVC Help
View File | Revision Log | Show Annotations | Download File | Root Listing
root/radiance/ray/doc/man/man1/ra_xyze.1
Revision: 1.4
Committed: Tue Sep 4 17:36:40 2007 UTC (16 years, 8 months ago) by greg
Branch: MAIN
CVS Tags: rad3R9
Changes since 1.3: +3 -3 lines
Log Message:
Added backslashes in front of hyphens (thanks to Bernd Zeimetz for his effort)

File Contents

# User Rev Content
1 greg 1.4 .\" RCSid "$Id: ra_xyze.1,v 1.3 2006/08/22 21:38:21 greg Exp $"
2 greg 1.1 .TH RA_XYZE 1 5/30/96 RADIANCE
3     .SH NAME
4     ra_xyze - convert between RADIANCE RGBE and XYZE formats
5     .SH SYNOPSIS
6     .B ra_xyze
7     [
8     .B \-r
9     ][
10     .B "\-e exposure"
11     ][
12 greg 1.3 .B \-o
13     ][
14 greg 1.1 .B \-c
15     |
16     .B \-u
17     ][
18     .B "\-p xr yr xg yg xb yb xw yw"
19     ]
20     [
21     .B input
22     [
23     .B output
24     ]
25     ]
26     .SH DESCRIPTION
27     .I Ra_xyze
28     converts between RADIANCE RGBE (red,green,blue,exponent) and XYZE
29     (CIE X,Y,Z,exponent) formats.
30     The
31     .I \-e
32     option specifies an exposure compensation, which may be given as
33     a decimal multiplier or in f-stops (powers of two).
34 greg 1.3 The
35     .I \-o
36     option may be used to specify original units, to which the exposure
37     compensation is applied.
38     Otherwise, the multiplier is in addition to any previous exposure adjustment.
39 greg 1.1 By default,
40     .I ra_xyze
41     produces a flat XYZE RADIANCE picture file from any type of RADIANCE
42     input picture.
43     To override these defaults, the
44     .I \-c
45     option may be used to specify run-length encoded output,
46     or the
47     .I \-u
48     option may be used to specify a flat output.
49     .PP
50     The
51     .I \-r
52     option causes
53     .I ra_xyze
54 greg 1.3 to produce a run-length encoded RGBE file instead, unless
55     .I \-u
56     is given, also, when it will produce a flat RGBE file.
57 greg 1.1 The
58     .I \-p
59     option may be used to override the standard RADIANCE RGB primary
60     colors to tailor the image for a particular output device or
61     representation.
62     The eight floating-point arguments to this option are the 1931
63     CIE (x,y) chromaticity coordinates of the three RGB primaries
64     plus the white point, in that order.
65     The new primaries will be recorded in the header of the output file,
66     so that the original information may be fully recovered later.
67     It is not necessary that the input file by in XYZE format.
68     Th
69     .I \-r
70     option may therefore be used to convert from one RGB primary
71     representation to another using the
72     .I \-p
73     option.
74     .PP
75     If the output file is missing, the standard output is used.
76     If the input file is missing as well, the standard input is used.
77     .SH NOTES
78     The CIE standard used is the 1931 2-degree observer, and the
79     correct output representation relies on the original RADIANCE
80     input description being defined properly in terms of the standard
81     RADIANCE RGB primaries, whose CIE (x,y) chromaticity values are
82     defined in the header file in src/common/color.h.
83     In this same file is a standard for the luminous efficacy of white
84     light (WHTEFFICACY), which is used as a conversion between lumens
85     and watts throughout RADIANCE.
86     This same factor is applied by
87     .I ra_xyze
88     when converting between the radiometric units of the RGBE format
89     and the photometric units of the XYZE format.
90     The purpose of this factor is to ensure that the Y component of
91     the CIE representation is luminance in units of candelas/meter^2.
92     .PP
93     Most of the RADIANCE picture filters should work uniformly on either
94     RGBE or XYZE files, so it is not necessary to convert back to RGBE
95     format except for conversion or display, in which case the correct
96     primaries for the chosen output device should be specified with the
97     .I \-p
98     option if they are known.
99     .SH EXAMPLES
100     To convert RGBE output from
101     .I rpict(1)
102     into run-length encoded XYZE format:
103     .IP "" .2i
104 greg 1.4 rpict [options] scene.oct | ra_xyze \-c > scene_xyz.pic
105 greg 1.1 .PP
106     To prepare a RADIANCE picture for display on a calibrated NTSC monitor:
107     .IP "" .2i
108 greg 1.4 ra_xyze \-r \-p .670 .330 .210 .710 .140 .080 .333 .333 stand.pic ntsc.pic
109 greg 1.1 .SH AUTHOR
110     Greg Ward
111     .SH BUGS
112     Any color correction applied to the original image is not removed
113     or translated by
114     .I ra_xyze,
115     and it may result in color shifts in the output.
116     If color preservation is important and the correction is unwanted,
117     it is best to remove it with
118     .I pfilt(1)
119     using the
120     .I \-er,
121     .I \-eg
122     and
123     .I \-eb
124     options first.
125     (Simply look at the header and apply the reciprocal primaries of all
126     COLORCORR= lines multiplied together.)
127     Better still, get the picture before color correction is applied.
128     .SH "SEE ALSO"
129     pfilt(1), ra_rgbe(1), rpict(1)