ViewVC Help
View File | Revision Log | Show Annotations | Download File | Root Listing
root/radiance/ray/doc/man/man1/mgf2rad.1
Revision: 1.2
Committed: Tue Dec 9 15:59:06 2003 UTC (20 years, 5 months ago) by greg
Branch: MAIN
CVS Tags: rad3R7P2, rad3R7P1, rad3R6, rad3R6P1, rad3R8
Changes since 1.1: +1 -1 lines
Log Message:
Fixed RCSid specification

File Contents

# User Rev Content
1 greg 1.2 .\" RCSid "$Id$"
2 greg 1.1 .TH MGF2RAD 1 4/12/95 RADIANCE
3     .SH NAME
4     mgf2rad - convert Materials and Geometry Format file to RADIANCE description
5     .SH SYNOPSIS
6     .B mgf2rad
7     [
8     .B "\-m matfile"
9     ][
10     .B "\-e mult"
11     ][
12     .B "\-g dist"
13     ]
14     [
15     .B input ..
16     ]
17     .SH DESCRIPTION
18     .I Mgf2rad
19     converts one or more Materials and Geometry Format (MGF)
20     files to a RADIANCE scene description.
21     By definition, all output dimensions are in meters.
22     The material names and properties
23     for the surfaces will be those assigned in MGF.
24     Any materials not defined in MGF will result in an error during
25     translation.
26     Light sources are described inline as IES luminaire files, and
27     .I mgf2rad
28     calls the program
29     .I ies2rad(1)
30     to translate these files.
31     If an IES file in turn contains an MGF description of the local
32     fixture geometry, this may result in a recursive call to
33     .I mgf2rad,
34     which is normal and should be transparent.
35     The only side-effect of this additional translation is the
36     appearance of other RADIANCE scene and data files produced
37     automatically by
38     .I ies2rad.
39     .PP
40     The
41     .I \-m
42     option may be used to put all the translated materials into a separate
43     RADIANCE file.
44     This is not always advisable, as any given material name may be
45     reused at different points in the MGF description, and writing them
46     to a separate file loses the contextual association between
47     materials and surfaces.
48     As long as unique material names are used throughout the MGF
49     description and material properties are not redefined, there
50     will be no problem.
51     Note that this is the only way to get all the translated materials
52     into a single file, since no output is produced for unreferenced
53     materials; i.e. translating just the MGF materials does not work.
54     .PP
55     The
56     .I \-e
57     option may be used to multiply all the emission values by the
58     given
59     .I mult
60     factor.
61     The
62     .I \-g
63     option may be used to establish a glow distance (in meters)
64     for all emitting surfaces.
65     These two options are employed principally by
66     .I ies2rad,
67     and are not generally useful to most users.
68     .SH EXAMPLE
69     To translate two MGF files into one RADIANCE materials file and
70     one geometry file:
71     .IP "" .2i
72     mgf2rad -m materials.rad building1.mgf building2.mgf > building1+2.rad
73     .PP
74     To create an octree directly from two MGF files and one RADIANCE
75     file:
76     .IP "" .2i
77     oconv '\\!mgf2rad materials.mgf scene.mgf' source.rad > scene.oct
78     .SH FILES
79     tmesh.cal Used to smooth polygonal geometry
80     .br
81     *.rad RADIANCE source descriptions created by ies2rad
82     .br
83     *.dat RADIANCE source data created by ies2rad
84     .br
85     source.cal Used for IES source coordinates
86     .SH AUTHOR
87     Greg Ward
88     .SH "SEE ALSO"
89     ies2rad(1), mgf2meta(1), obj2rad(1), oconv(1), rad2mgf(1), xform(1)
90     .PP
91     MGF web site "http://radsite.lbl.gov/mgf/HOME.html"