# Line 5 | Line 5 | macbethcal - compute color compensation based on measu
5   .SH SYNOPSIS
6   .B macbethcal
7   [
8 < .B "\-d debug.pic"
8 > .B "\-d debug.hdr"
9   ][
10   .B "\-p xul yul xur yur xll yll xlr ylr"
11   ]
12 < .B scannedin.pic
12 > .B scannedin.hdr
13   [
14   .B calibout.cal
15   ]
# Line 17 | Line 17 | macbethcal - compute color compensation based on measu
17   .B macbethcal
18   .B \-c
19   [
20 < .B "\-d debug.pic"
20 > .B "\-d debug.hdr"
21   ]
22   [
23   .B measured.xyY
# Line 82 | Line 82 | row of the chart.
82   Computing a mapping from measured colors is usually more convenient
83   when calibrating a particular output device.
84   This is accomplished by printing the picture
85 < .I macbeth_spec.pic
85 > .I macbeth_spec.hdr
86   (which may be found in the standard RADIANCE library directory in
87   the lib subdirectory) and measuring the output with a chroma meter
88   or spectrophotometer.
# Line 201 | Line 201 | The chart sells for under $50 US at the time of this w
201   To compute a calibration for a FunkyThing scanner and check the
202   results:
203   .IP "" .2i
204 < ra_tiff \-r mbscan.tif mbscan.pic
204 > ra_tiff \-r mbscan.tif mbscan.hdr
205   .br
206 < macbethcal \-d debug.pic mbscan.pic FunkyThing.cal
206 > macbethcal \-d debug.hdr mbscan.hdr FunkyThing.cal
207   .br
208 < ximage debug.pic
208 > ximage debug.hdr
209   .PP
210   To apply this computed calibration to another scanned image:
211   .IP "" .2i
212 < ra_tiff \-r another.tif | pcomb \-f FunkyThing.cal \- > another_calib.pic
212 > ra_tiff \-r another.tif | pcomb \-f FunkyThing.cal \- > another_calib.hdr
213   .PP
214   To compute a calibration file for the BigWhiz film recorder, after
215 < taking measurements of a slide made from macbeth_spec.pic:
215 > taking measurements of a slide made from macbeth_spec.hdr:
216   .IP "" .2i
217   macbethcal \-c macbeth_spec.xyY BigWhiz.cal
218   .PP
219   To prepare a picture prior to output on the same film recorder:
220   .IP "" .2i
221 < pcomb \-f BigWhiz.cal standard.pic > toprint.pic
221 > pcomb \-f BigWhiz.cal standard.hdr > toprint.hdr
222   .PP
223   To use
224   .I pcond(1)
225   to also adjust the image for human response:
226   .IP "" .2i
227 < pcond \-f BigWhiz.cal \-h standard.pic > toprint.pic
227 > pcond \-f BigWhiz.cal \-h standard.hdr > toprint.hdr
228   .SH AUTHOR
229   Greg Ward
230   .br