| 1 |
greg |
1.2 |
.\" RCSid $Id: genklemsamp.1,v 1.1 2009/06/14 00:33:15 greg Exp $
|
| 2 |
greg |
1.1 |
.TH GENKLEMSAMP 1 6/13/09 RADIANCE
|
| 3 |
|
|
.SH NAME
|
| 4 |
|
|
genklemsamp - generate ray samples over surfaces using Klems BSDF basis
|
| 5 |
|
|
.SH SYNOPSIS
|
| 6 |
|
|
.B genklemsamp
|
| 7 |
|
|
[
|
| 8 |
|
|
.B "\-c N"
|
| 9 |
|
|
][
|
| 10 |
|
|
.B "\-f{a|f|d}"
|
| 11 |
|
|
]
|
| 12 |
|
|
[
|
| 13 |
|
|
.B "view opts"
|
| 14 |
|
|
]
|
| 15 |
|
|
[
|
| 16 |
|
|
.B "geom.rad .."
|
| 17 |
|
|
]
|
| 18 |
|
|
.SH DESCRIPTION
|
| 19 |
|
|
.I Genklemsamp
|
| 20 |
|
|
generates ray origins and directions to sample planar surfaces
|
| 21 |
|
|
needed to determine incident radiances or daylight coefficients.
|
| 22 |
|
|
This command is typically used in conjunction with
|
| 23 |
|
|
.I rtcontrib(1)
|
| 24 |
|
|
to analyze exterior daylight coefficients
|
| 25 |
|
|
for an annual simulation.
|
| 26 |
|
|
.PP
|
| 27 |
|
|
The view options are needed to specify (at minimum) the view direction,
|
| 28 |
|
|
which corresponds to the orientation of the surfaces, and the view up
|
| 29 |
|
|
vector, which corresponds to the azimuth=90-degree position on the Klems
|
| 30 |
|
|
sampling hemisphere.
|
| 31 |
greg |
1.2 |
The view fore clipping distance is also quite useful, as it provides
|
| 32 |
|
|
a means to pass through some thickness in a fenestration system before
|
| 33 |
|
|
samples are sent out.
|
| 34 |
|
|
Other view options such as the view type and aft
|
| 35 |
|
|
clipping distance are overridden or ignored.
|
| 36 |
greg |
1.1 |
.PP
|
| 37 |
|
|
If no Radiance scene files are provided, then the specified parallel
|
| 38 |
|
|
view defines the width, height, center, and orientation of the window
|
| 39 |
|
|
or facade of interest.
|
| 40 |
|
|
If one or more scene files are given, they
|
| 41 |
|
|
are presumed to contain planar surfaces over which
|
| 42 |
|
|
.I genklemsamp
|
| 43 |
|
|
will originate samples.
|
| 44 |
|
|
The sampled surface normals must correspond to the specified
|
| 45 |
|
|
view direction, and unaligned surfaces are silently ignored.
|
| 46 |
|
|
.PP
|
| 47 |
|
|
The
|
| 48 |
|
|
.I \-c
|
| 49 |
|
|
option specifies the number of rays to sample per Klems direction.
|
| 50 |
|
|
These samples will be distributed evenly over the surface(s).
|
| 51 |
|
|
The default setting is 1000.
|
| 52 |
|
|
.PP
|
| 53 |
|
|
The
|
| 54 |
|
|
.I \-ff
|
| 55 |
|
|
option specifies that output rays should be generated as 32-bit IEEE binary
|
| 56 |
|
|
float values.
|
| 57 |
|
|
This may be more efficient if passed directly to
|
| 58 |
|
|
.I rtcontrib
|
| 59 |
|
|
or
|
| 60 |
|
|
.I rtrace(1)
|
| 61 |
|
|
with the same option.
|
| 62 |
|
|
Likewise, the
|
| 63 |
|
|
.I \-fd
|
| 64 |
|
|
option specifies 64-bit IEEE binary double values.
|
| 65 |
|
|
The default setting of
|
| 66 |
|
|
.I \-fa
|
| 67 |
|
|
produces ASCII floating point values.
|
| 68 |
|
|
.SH EXAMPLE
|
| 69 |
|
|
To generate 500 samples per direction over a set of south-facing windows and
|
| 70 |
|
|
pass to
|
| 71 |
|
|
.I rtcontrib
|
| 72 |
|
|
to compute daylight coefficients in a matrix:
|
| 73 |
|
|
.IP "" .2i
|
| 74 |
|
|
genklemsamp -c 500 -vd 0 -1 0 -vu 0 0 1 south_windows.rad
|
| 75 |
|
|
| rtcontrib -c 500 -f tregenza.cal -b tbin -bn 146 exterior.oct > Dsouth.dat
|
| 76 |
|
|
.SH AUTHOR
|
| 77 |
|
|
Greg Ward
|
| 78 |
|
|
.SH "SEE ALSO"
|
| 79 |
|
|
mkillum(1), rtcontrib(1), rtrace(1), vwrays(1)
|